<LOGO>
FM Transmitter Measurement Report
Created: 2026-01-18 00-27-16
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
88.50 MHz 5/5, 59 dBuV Couleur3
Pilot RDS Phase Difference
6.6 kHz 2.0 kHz -34 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 70 kHz 19258 9,0041
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,0 dBr 2,37 dBr 3,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Couleur3" 43D3 0 (No PTY) 1 0 1 1 0:27, 18.01.2026
RT
" "
AF EON
98.5, 101.4, 104.2, 104.4, 104.7, 105.6 MHz 43D1, 43D2
FM Scope Max at: 70 kHz MIN: 11 kHz % above 76 kHz: 9,0041 Acquired: 2026/01/18 0.26.11 Total samples: 19258 Equivalent time: 0:16:02 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600